hydroelectric plant, water power plant
switch-cabinet

Switch cabinet 

 VPK Series

The switch cabinet adopts brands like Schneider and HANGSHEN ELECTRIC circuit breaker. It has standard GGD cabinet structure, profile frame, simple wiring, and is easily used with beautiful appearance. Its switch brand can be selected according to user requirements.

Parallel cabinet  

VPB series

The parallel cabinet adopts a fully automatic control parallel system including GAC synchronization module and GAC power distribution module. It adopts thin as produced from Schneider and HANGSHEN ELECTRIC. It has features of standard GGD cabinet structure, profile frame, silver contacts, and short switching time. It can meet the requirements of various power applications.

parallel-cabinet.webp
automatic-switch-cabinet

Automatic switch cabinet  

VPA series

The automatic switch cabinet (ATS) adopts French Sugomi and Yangzhou Aiskai transfer switches. The standard GGD cabinet structure, profile frame silver contacts, and short switching time meet the requirements of various power applications.

High-voltage switch cabinet

KYN28-630A

The high-voltage switch cabinet adopts VD4 vacuum circuit breakers produced by ABB, and the main insulation is designed with composite insulation to meet the “five prevention requirements” for safety. The cabinet shell is made of imported aluminum zinc coated plate, which is resistant to oxidation and corrosion; Adopting an assembled structure, connected by rivets and high-strength bolts, it has high mechanical strength and is suitable for various power environments.

high-voltage-switch-cabinet.webp
PT-cabinet-.webp

PT cabinet 

KYN28-PT

The PT cabinet adopts high-quality voltage transformers to ensure accurate voltage measurement,and is equipped with corresponding fuses, isolation switches, relay protection,and lightning arresters. Standard GGD cabinet structure, profile frame, simple wiring, easy to use, and beautiful appearance.

Grounding resistor cabinet 

VP-GNR6062/10A

The grounding resistor cabinet is a complete set of equipment designed for high-voltage generators with high resistance grounding at the neutral point.The voltage level is mainly between 6kV and 20kV. When the stator is grounded at a certain point, the grounding current can be limited to a very small value, and the transient over voltage of arc grounding can be effectively suppressed.

Grounding-resistor-cabinet.
ATS-side-cabinet

ATS side opening cabinet  

The unit is controlled by a microcomputer and automatically starts in the event of a power outage. The generator set automatically closes and delivers power; When there is a mains call, the generator set automatically shuts down and cools down,achieving unmanned automatic protection and operation.

  • Equipped with fire emergency use function, the fire alarm automatically starts the unit. If there is a power outage due to a fire,the fire pump will immediately be powered on and ready for power supply.
  • Control screen LCD display function, displaying water temperature, oil pressure, power, voltage, current, frequency, speed, power factor, phase sequence, battery voltage, etc., and has AMF mains power detection function. Abnormal power supply voltage can trigger an alarm or the device can operate (configurable).
  • Install manual start function, which can achieve manual start, manual high and low speed, manual shutdown, and manual opening, ensuring that the unit can still be used in emergency situations when the automation accessories fail.
  • Automatic conversion function between urban power and power generation dual sources.
  • The unit has 21 automatic protection functions.
  • Equipped with floating charging function, it automatically charges and stops charging when the cut-off voltage is reached.

 

Controller

controller.webp

滚动至顶部